Item Specification
Communications power supply voltage 14 to 26.4 VDC
I/O power supply voltage *1 20.4 to 26.4 VDC (24 VDC -15%/+10%)
Noise immunity Conforms to IEC 61000-4-4, 2 kV (power line).
Vibration resistance 10 to 60 Hz with double-amplitude of 0.7 mm, 60 to 150 Hz and 50 m/s2 in X, Y,
and Z directions for 80 min each
Shock resistance 150 m/s2 (3 times each in 6 directions on 3 axes)
Dielectric strength 500 VAC (between isolated circuits)
Insulation resistance 20 MΩ min. (between isolated circuits)
Ambient operating temperature -10 to 55°C
Ambient operating humidity 25% to 85% (with no condensation)
Ambient operating atmosphere No corrosive gases
Storage temperature -25 to 65°C
Storage humidity 25% to 85% (with no condensation)
Terminal block screw tightening
torque *2
M3 wiring screws: 0.5 Nm
M3 mounting screws: 0.5 Nm
Installation Mounted on 35-mm DIN Track or Mounting Bracket, or secured with M4 screws
(depending on model)

Description

XWT-ID16-1 OMRON Automation and Safety

รายละเอียดสินค้า / Product Details

OMRON XWT-OD16-1 Manual And Instructions
XWT-OD16-1 datasheetPDF datasheet
XWT-OD16-1 PROGRAMMING MANUAL
XWT-OD16-1 INSTRUCTION Manual

OMRON XWT-OD16-1 Product information and technical parameters:
Brand: OMRON
Name: Expansion Units
Model: XWT-OD16-1
Name: Expansion Units.
Specifications: Outputs;
16 outputs; PNP;
One Expansion Unit can be,
mounted to one CRT1-ID16(-1),
CRT1-OD16(-1), CRT1-ROS16,
or CRT1-ROF16 Digital I/O Slave.
Standards: CE, UC, UC1, N.
“Easy” and “Flexible” system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.

 

Input/Output: Outputs.
Internal I/O circuit common: NPN (– common).
I/O points: 8 points.
I/O connection method: Sensor connector.
Rated voltage for I/O power supply: 24 VDC.
Eight Waterproof Terminal Models.
Emphasizing Cost Efficiency.
Reduced Labor.
Connection using connectors reduces the lead time,
required for installation OMRON XWT-OD16-1. No tools are required for,
connection to a variety of devices XWT-OD16-1
Reduced Wiring.
Signal line wiring has been reduced so that the,
Terminal can be mounted closer to sensors and,
other devices.
Relay Box not Required.
Environment-resistant, dust-tight, drip-proof,
construction (IP67) enables direct on-site,
mounting.
Easier Maintenance.
Significant reductions not only in setup time but also,
maintenance time OMRON XWT-OD16-1.
Reduced Space, Improved Operability,
Compact design (160 x 54 mm (W x H)) (8-point models).
Settings and connections can be performed using,
the switch and connectors on the front side of the Terminal.
System Configuration. Name: Two-tier Screw Terminal Block.
Specifications: Outputs; 8 outputs; PNP.
“Easy” and “Flexible” system expansion,
with linked CC-Link and CompoNet OMRON XWT-OD16-1.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: I/O; NPN (input: + common,
output: – common); Input:
8 points/Output: 8 points.
I/O connections: M3 screw terminals.
Rated internal circcuit power supply voltage:
Supplied from Basic Unit XWT-OD16-1.
I/O power supply voltage: 24 VDC.
A Smart Slave with a 3-tier Terminal,
Block That Means Wiring Locations,
Are Easy to Understand with No,
Sharing of Terminals.
Easy wiring with no sharing of terminals XWT-OD16-1.
Easy-to-understand wiring locations.
No relay terminal block terminals required.
Detachable cassette-type circuit sections.