Product description

Description

Omron CPU Unit CJ2M-CPU12

  • Extended Product Type: CJ2
  • Product ID: CJ2M-CPU12
  • OMRON Type Designation: CJ2
  • Description: CONTROL LOGIC RS232 10K STEPS

Features

• Five variations in program capacity from 5K steps to 60K steps; scale the CPU to your application needs.

• Faster processors; LD instruction execution time is reduced to 40 ns, floating point trigonometrics in less than 1 μs.

• Optional Pulse I/O Modules can be mounted to enable positioning functions for up to four axes. The module provides high-speed counters, interrupt inputs and pulse train/PWM outputs. (CJ2M CPU Units with Unit Version 2.0 or Later)

• Faster Function Block calls and execution, faster interrupt handling, less overhead time.

• Added execution memory for Function Blocks allows structured, object-oriented programming even in entry-level CPUs.

• General-purpose Ethernet port supports EtherNet/IP tag-based data links, connection to Support Software, communications between PLCs, FTP data transfers, and more (CJ2M-CPU3[]).

• Standard USB port on all models allows Support Software to connect directly through standard USB cable.

• A Serial Option Module can be mounted to add RS-232C or RS-422A/485 communications ports (CJ2M-CPU3[]).

• Compatible with all existing CJ1 power supply-, I/O-, control- and communication units.

International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.

Specification

  • CPU Unit Dimensions: 90 mm × 75 mm × 31 mm
  • Weight: 130 g
  • Current Consumption: 5 VDC, 0.5 A
  • User Memory: 10K steps

[Enclosure] Mounted in a panel
[Grounding] Less than 100 Ohm
[Weight] 130g or less
[Current Consumption] 5 VDC, 0.5 A
[Operation Environment]
Ambient Operating Temperature: 0 to 55CEL
Ambient Operating Humidity: 10% to 90% (with no condensation)
Atmosphere: Must be free from corrosive gases.
Ambient Storage Temperature: – 20 to 70 CEL(excluding battery)
Altitude: 2,000 m or less
Pollution Degree: 2 or less: Conforms to JIS B3502 and IEC 61131-2.
Noise Immunity: 2 kV on power supply line (Conforms to IEC 61000-4-4.)
Overvoltage Category: Category II: Conforms to JIS B3502 and IEC 61131-2.
EMC Immunity Level: Zone B
Vibration Resistance: Conforms to IEC60068-2-6.
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz
Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total)
Shock Resistance: Conforms to IEC60068-2-27. 147 m/s2, 3 times in X, Y, and Z directions (100 m/s2 for Relay Output Units)
[Applicable Standards] Conforms to cULus, NK, LR and EC Directives.
[I/O capacity/Mountable Units(Expansion Racks)] 2,560 points/ 40 Units(3 Expansion Racks max.)
[Program capacity] 10K steps
[Data memory capacity] 64K words
DM: 32K words
EM: 32K words x 1 banks
[LD instruction execution time] 0.04 microsecond
[Current consumption (A)] 5V: 0.5
[Standards] UC1, N, L, CE

Omron CJ2M-CPU13 Europe Automation and Safety

Product description

Description

Programmable Logic Controller (PLC) CPU unit – OMRON (SYSMAC CJ2M series – CJ2M-CPU1[]) – 20Ksteps (Program) + 32K words (Data) memory capacity – can connect with 2560 x I/O points – with RS-232C communication capability – with 9-pin D-Sub connector – DIN rail mounting

OverviewCPU – CJ2M-CPU1

Featured List:
Increased performance, and increased memory capacity
Up to 40 I/O unit on any CPU
Pulse I/O Modules add position control functions to any CPU
USB for plug-and-play access to the PLC
All models available with or without Ethernet port
Choice of serial port plug-in modules
Compatible with all existing CJ1 power supply, I/O, control and communication units

[Enclosure] Mounted in a panel
[Grounding] Less than 100 Ohm
[Weight] 130g or less
[Current Consumption] 5 VDC, 0.5 A
[Operation Environment]
Ambient Operating Temperature: 0 to 55CEL
Ambient Operating Humidity: 10% to 90% (with no condensation)
Atmosphere: Must be free from corrosive gases.
Ambient Storage Temperature: – 20 to 70 CEL(excluding battery)
Altitude: 2,000 m or less
Pollution Degree: 2 or less: Conforms to JIS B3502 and IEC 61131-2.
Noise Immunity: 2 kV on power supply line (Conforms to IEC 61000-4-4.)
Overvoltage Category: Category II: Conforms to JIS B3502 and IEC 61131-2.
EMC Immunity Level: Zone B
Vibration Resistance: Conforms to IEC60068-2-6.
5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz
Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total)
Shock Resistance: Conforms to IEC60068-2-27. 147 m/s2, 3 times in X, Y, and Z directions (100 m/s2 for Relay Output Units)
[Applicable Standards] Conforms to cULus, NK, LR and EC Directives.
[I/O capacity/Mountable Units(Expansion Racks)] 2,560 points/ 40 Units(3 Expansion Racks max.)
[Program capacity] 20K steps
[Data memory capacity] 64K words
DM: 32K words
EM: 32K words x 1 banks
[LD instruction execution time] 0.04 microsecond
[Current consumption (A)] 5V: 0.5
[Standards] UC1, N, L, CE