Omron CJ1W-AD041-V1 CJ1W-AD081-V1 Europe Automation and Safety

Omron CJ1W-AD041-V1 CJ1W-AD081-V1 Europe Automation and Safety

Omron CJ1W-AD041-V1 Europe Automation and Safety

  • Analog voltage and current input unit – OMRON (SYSMAC CJ1 series – CJ1W-AD) – 4I/O [4AI (4 x analog inputs (1-5Vdc / 0-5Vdc / 0-10Vdc /-10…+10Vdc / 4-20mA; 1/8000 resolution; 250µs conversion time) – High-speed conversion)] – DIN rail mounting
  • Product No. : CJ1W-AD041-V1
  • Product Type : Analog Output Units
  • Isolation *1 : Between I/O and Controller signals : Photocoupler (No isolation between I/O signals.)
  • External terminals: 18-point detachable terminal block (M3 screws)
  • Power consumption : 420 mA max. at 5 VDC
  • Dimensions (W × H × D) : 3.1 cm × 9.0 cm × 6.5 cm
  • General specifications : Conforms to general specifications for CJ Series.
  • Input specifications
    • Number of analog inputs : 4
    • Input signal range *2 : 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA, *3
    • Maximum rated input (for 1 point)
      • Voltage Input : ±15 V
      • Current Input : ±30 mA
    • Input impedance : Voltage Input: 1 MO min. Current Input : 250 O (rated value)
    • Resolution : 4,000/8,000 *6
    • Converted output data : 16-bit binary data
    • Accuracy *7 25°C *8 : Voltage Input : ±0.2% of F.S.Current Input: ±0.4% of F.S
    • 0°C to 55°C : Voltage Input : ±0.4% of F.S.Current Input: ±0.6% of F.S
    • A/D conversion period *9 : 1 ms/250 µs per point *6
  • Input functions
    • Mean value processing : Stores the last “n” data conversions in the buffer, and stores the mean value of the conversion values. Buffer number: n = 2, 4, 8, 16, 32, 64
    • Peak value holding : Stores the maximum conversion value while the Peak Value Hold Bit is ON.
    • Input disconnection detection : Detects the disconnection and turns ON the Disconnection Detection Flag. *10
    • Offset/gain Adjustment : Supported
  • Weight : 0.14 Kg max

Specifications

I/O systemCJ I/O Bus
Expansion unit typeSpecial I/O Unit
Type of moduleAnalog I/O
Number of analog inputs4
Temperature input typeNone
Linear analog input type-10 to 10 V, 0 to 10 V, 0 to 5 V, 1 to 5 V, 4 to 20 mA
Resolution of the analog inputs13 Bit
Number of analog outputs0
Linear analog output typeNone
I/O connection typeScrew
Number of I/O connectors1
Detachable I/O connector
Suitable for safety functions
Height90 mm
Width31 mm
Depth89 mm

Omron CJ1W-AD081-V1 Europe Automation and Safety

Omron Electronics CJ1 Series Programmable Logic Controller Expansion Module, 8-analog input points @ 1/8000 resolution, 250 s/point max, 18-point detachable terminal block (M3) connection, 1 allocated unit, 420mA max @ 24/DC

  • Manufacturer: Omron
  • Product Family: CJ Series
  • Product Type: Special I/O Unit

Specifications

I/O systemCJ I/O Bus
Expansion unit typeSpecial I/O Unit
Type of moduleAnalog I/O
Number of analog inputs8
Temperature input typeNone
Linear analog input type-10 to 10 V, 0 to 10 V, 0 to 5 V, 1 to 5 V, 4 to 20 mA
Resolution of the analog inputs13 Bit
Number of analog outputs0
Linear analog output typeNone
I/O connection typeScrew
Number of I/O connectors1
Detachable I/O connector
Suitable for safety functions
Height90 mm
Width31 mm
Depth89 mm

CJ-Series Analog I/O Unit

CJ1W-AD/DA/MAD



Analog Input Units

  • Input up to eight analog signals with one Unit.
  • Functions include line disconnection detection, averaging, peak value holding, offset/gain adjustment, and scaling. (Offset/gain adjustment is not supported by the CJ1W-AD042. Scaling is supported only by the CJ1W-AD042.)
  • High-speed A/D conversion in 20 μs/point with direct conversion function * (CJ1W-AD042 only).

Analog Output Units

  • Output up to eight analog signals with one Unit.
  • Functions include output holding, offset/gain adjustment, and scaling. (Offset/gain adjustment is not supported by the CJ1W-DA042V. Scaling is supported only by the CJ1W-DA08V/DA08C/DA042V.)
  • High-speed D/A conversion in 20 μs/point with direct conversion function * (CJ1W-DA042V only).

Analog I/O Units

  • Input up to four analog signals and output up to two analog signals with one Unit.
  • Functions include line disconnection detection, input averaging, scaling, input peak value holding, output holding, ratio conversion, and offset/gain adjustment.

* Direct Conversion Instructions for High-speed type can be used to create a consistent response time from input through data processing and output. With the Machine Automation Controller NJ-series, the direct conversion function cannot be used. This function is supported only by the CJ-series CPU Unit.